WashBench

Soft wash mix calculator

Work out how much sodium hypochlorite (SH) and water to mix for a target strength, what a downstream injector really puts on the wall, and your injector's true draw from a bucket test. Formulas shown, sources dated.

Last checked · First published · Sources

This page has no affiliate links. Product and supplier pages are cited only as sources for published specs.

Safety first. Sodium hypochlorite (SH) is corrosive. The 12.5% SDS from HASA calls for goggles or a face shield and chemical-resistant gloves. It also warns that mixing SH with ammonia, acids or detergents releases chlorine gas, so use only surfactants whose label says they are made for use with SH. Always follow the product label and the surface manufacturer's instructions, and test a small spot first. This calculator does the arithmetic. It does not tell you a mix is safe for a given surface.

Quick answer

For a 1% batch from 12.5% SH, use 4 gal SH + 46 gal water in a 50 gal tank, or 8 + 92 in a 100 gal tank. That is about 1 part SH to 11.5 parts water. Through a fixed 10% downstream injector, straight 12.5% SH lands at about 1.25% on the wall (12.5 × 0.10). Both figures assume your SH really is 12.5%. Old or hot-stored SH is often weaker (see below).

1. Batch mix (dedicated pump or sprayer drawing from a tank)

Enter values above.

2. Downstream injector: what reaches the wall

Enter values above.

3. Bucket test: your injector's real draw

Real injectors rarely draw exactly their rating. Hose length, nozzle and machine flow all change it. Put a measured amount of water in the draw bucket, spray with the soap nozzle for a timed period, then measure how much was pulled.

Enter values above.

The formulas

Everything above is ordinary dilution arithmetic. Strength × volume of SH stays the same when you add water:

Cstock × VSH = Ctarget × Vtotal
VSH = Vtotal × Ctarget ÷ Cstock
Vwater = Vtotal − VSH
Ratio = 1 part SH : (Vwater ÷ VSH) parts water

Example: 50 gal at 1% from 12.5% gives VSH = 50 × 1 ÷ 12.5 = 4 gal, so water = 46 gal. That matches the published batch formula from Expert Power Wash: “gallons of SH = tank size × target % ÷ 12.5”.

Downstream: Cwall = Cbucket × d   (d = draw as a fraction, e.g. 10% → 0.10)
Bucket test: q = gallons pulled ÷ minutes;  d = q ÷ (GPM + q)

The bucket-test formula treats chemical drawn as extra liquid joining the pump's flow, which is how a downstream injector works: chemical enters after the pump. Example: 0.5 gal pulled in 1.5 min on a 4 GPM machine gives q ≈ 0.33 GPM and d ≈ 0.33 ÷ 4.33 ≈ 7.7%. Straight 12.5% SH would then reach the wall at about 0.96%, not 1.25%.

Percentages here are treated as simple volume blends, which is how trade mixing charts work. The SDS strengths are stated by weight, so treat every result as a close estimate. Your surface test spot is the final check.

How strong is your SH really?

Published strengths (checked 19 November 2026)
Product typeStated SH strengthSource
Regular household bleach5%–9% (“most household bleach”)CDC
Pool “liquid chlorine” (HASACHLOR)12.5% by weightHASA SDS, rev. 08/24/2026
Pool shock (OnLine Swim Shock)12.5%OnLine Packaging SDS, rev. 06/22/2021

SH loses strength in storage. A Florida Water Resources Journal technical article says that “at 80°F, 12.5 percent sodium hypochlorite will degrade about 20 percent within two weeks, leaving only a 10 percent solution”. Hill Brothers Chemical says the decomposition rate rises 3.5× for every 10°C (18°F) rise in storage temperature, and recommends opaque containers kept in shade. In practice, if the drum has been sitting in a hot truck, enter a lower stock strength above, or test it with strips made for high-range chlorine. If you enter 10% instead of 12.5% for a 50 gal 1% batch, you need 5 gal SH instead of 4.

What strength do trade sources publish?

There is no single official number. Here is what the sources we read publish, side by side. The surface manufacturer's instructions and the SH product label come first.

SurfaceExpert Power Wash “Softwash Percent Guide”Softwash Technologies (“at the wall”)Roofing industry (ARMA)
Vinyl siding1%–2%About 1% (0.5%–1.5% by growth)—
Stucco / EIFS (Dryvit)2%–5% by staining0.75%–1.5% (cites Sto 0.55%–1.2%, EDI 1.25%)—
Brick / masonry2%–3%1% maintenance, 2%–4% moderate, 4%–6% heavy—
Asphalt shingle roof4%–6% by staining3%–6%, through a dedicated pump50:50 laundry-strength bleach and water, 15–20 min dwell, never pressure-wash

Our arithmetic, not a source claim: ARMA's 50:50 mix with household bleach at 5%–9% (CDC range) comes to roughly 2.5%–4.5% SH. The same 50:50 mix made with 12.5% stock would be about 6.25%. Softwash Technologies makes the same point: the 50/50 rule “was written for household bleach”.

Softwash Technologies also notes that “a standard downstream injector tops out near 1.5 to 2% at the wall”. If calculator 2 says you need a bucket stronger than your stock, you have hit that ceiling. Roof-strength mixes need a dedicated soft wash pump and the batch calculator.

Mixing order and units

  • Fill order published by Expert Power Wash: water first, then SH, then surfactant last so the tank does not foam over.
  • Surfactant is dosed per gallon of finished mix, at the rate on its own label. Calculator 1 takes that rate as an input instead of guessing it.
  • Unit conversion: 1 US gallon = 128 fl oz = 4 quarts.
  • CDC advice for diluted bleach: make a new solution daily, because it is less effective after more than 24 hours mixed with water.

Sources

Each source was opened and read on the date shown. Spotted something out of date? Tell us.

  1. Cleaning and Disinfecting with Bleach — U.S. Centers for Disease Control and Prevention (CDC). Accessed 19 November 2026.
    “Most household bleach contains 5%–9% sodium hypochlorite.” Also: never mix bleach with other cleaners.
  2. HASACHLOR Safety Data Sheet (12.5% Sodium Hypochlorite), revision 08/24/2026 — HASA Inc.. Accessed 19 November 2026.
    Section 3 lists sodium hypochlorite at 12.5% by weight. Section 7: mixing with ammonia, acids, detergents etc. releases chlorine gas. Section 8: goggles or face shield and chemical-resistant gloves.
  3. OnLine Swim Shock 12.50% Sodium Hypochlorite SDS (rev. 06/22/2021) — OnLine Packaging, Inc. (hosted by Pooltown). Accessed 19 November 2026.
    A second 12.5% pool chlorine composition: 12.5% sodium hypochlorite, 87.5% water.
  4. Sodium hypochlorite design and degradation (Florida Water Resources Journal technical article) — Florida Water Resources Journal. Accessed 19 November 2026.
    “At 80°F, 12.5 percent sodium hypochlorite will degrade about 20 percent within two weeks, leaving only a 10 percent solution.”
  5. Sodium Hypochlorite FAQs — Hill Brothers Chemical Company. Accessed 19 November 2026.
    Decomposition rate rises by a factor of 3.5 for every 10°C increase in storage temperature. Store in opaque containers in shade.
  6. Algae & Moss Prevention and Cleaning for Asphalt Roofing Systems — Asphalt Roofing Manufacturers Association (ARMA). Accessed 19 November 2026.
    50:50 mix of laundry-strength liquid chlorine bleach and water, 15–20 minute dwell, low-pressure rinse. Never pressure-wash asphalt shingles.
  7. Technical Bulletin: Algae Discoloration of Roofs (revised June 2024) — ARMA. Accessed 19 November 2026.
    Mixing directions vary among shingle manufacturers. Leave on at least 15 and no more than 20 minutes.
  8. Downstream Fixed 10% 3–5 GPM Chemical Draw Injector (product specification) — American Pressure Systems. Accessed 19 November 2026.
    Fixed 10% draw ratio, 3–5 GPM, 4500 PSI max; draws only with a size 40.0 soap nozzle.
  9. Soft Wash Mix Calculator and Softwash Percent Guide — Expert Power Wash (equipment supplier, Oregon City, OR). Accessed 19 November 2026.
    Batch formula “gallons of SH = tank size × target % ÷ 12.5” and a published 1–6% strength guide by surface.
  10. Soft Wash Mix by Surface: The Number at the Wall — Softwash Technologies (equipment supplier, Jensen Beach, FL). Accessed 19 November 2026.
    Vinyl siding about 1% (0.5–1.5%) at the wall; shingle roofs 3–6% through a dedicated pump; a standard downstream injector tops out near 1.5–2% at the wall.

More calculators & tools pages are on the way. See the Calculators & tools hub.